Permit guide
Site plan for a permit in Santa Monica, CA
What Santa Monica's own pages say about sheds, decks and the site plan that goes with the permit, quoted word for word with a link to each page. Then type your address and draw yours to scale for $29.
Can you use our sheet here?
The city's pages do not say who must draw a shed or fence plot plan, but its plot plan guide's title block has a line for an architect's, engineer's or designer's seal, so ask the city in writing. A deck 30 inches or higher, an addition or a two-story accessory building needs plans stamped by a California architect or engineer.
Do you need a permit for a shed, deck or fence in Santa Monica?
A one-story detached shed or other accessory structure under 14 feet high, with no utilities and under 120 square feet, needs no building permit, but it must still meet the zoning rules for accessory structures. A larger accessory structure, or added floor area on one, goes through Medium Plan Review. Platforms and walkways no more than 30 inches above grade need no permit. The city's plan review thresholds page exempts freestanding fences up to seven feet, while its homeowner guide says six feet; ask the city in writing before you build a fence between the two.
What a Santa Monica plot plan should show
The city's plot plan guide asks for the lot's dimensions with each property line labelled PL, the footprint, use and zoning district of every structure, every setback measured from the property lines, a north arrow with north at the top, easements, a lot coverage calculation, and arrows for roof slope and drainage. It asks for a sheet between 11 by 17 inches and 24 by 36 inches; our Santa Monica sheet always prints on 11 by 17. The city also has a separate site plan guide for larger projects, which we could not open, and the pages we read do not say which of the two an accessory structure needs. Our sheet draws the lot from the county's parcel record, to scale, with each side's length, the lot area, the north arrow and the distances from what you place to each lot line. You add the zoning district, easements, the lot coverage figure and the drainage arrows.
Who can draw it
None of the pages we read says who must draw the plot plan. The homeowner guide says plans for nonstructural work, such as replacing doors and windows, can be drawn by anyone, and that plans and calculations for structural work must be stamped by a California-licensed architect or engineer. For a new accessory structure, a two-story project needs a structural analysis by a licensed structural engineer. So structural work, such as a deck 30 inches or more high (the homeowner guide exempts only decks "less than 30 inches in height when constructed on level grade"), an addition or a two-story accessory building, needs plans and calculations stamped by a California-licensed architect or engineer, and our sheet does not replace them. The plot plan guide, last revised in 2001, lists an "architect/engineer/designer's seal" in its title block. It names a designer alongside architects and engineers, and it does not say a license is needed. Our sheet is not a survey.
What needs a permit in Santa Monica
The plan review thresholds page exempts freestanding fences up to seven feet and concrete or masonry walls up to four feet.
“Exterior freestanding fences seven feet or less in height, and concrete or masonry walls 4 feet or less in height.”
The homeowner guide gives six feet for fences and walls.
“Exterior freestanding walls and fences not over six feet high, when measured from the bottom of the footing to the top of the wall”
Platforms and walkways no more than 30 inches above grade, over no basement or story below, need no building permit.
“Platforms, driveways, and walkways not more than 30 inches above grade and not over any basement or story below.”
A new accessory structure, or added floor area on one, goes through Medium Plan Review.
“Medium Plan Review”
Sheds that need no building permit
A one-story detached accessory structure under 14 feet high, with no utilities and under 120 square feet, needs no building permit; zoning review may still apply.
“1-story detached accessory structure less than 14-feet in height with no utilities and less than 120SF.”
The zoning rules for accessory structures apply even when no building permit is needed.
“Compliance with zoning requirements of SMMC Section 9.21.020 is required regardless of whether or not structure requires a building permit.”
What the site plan must show
The city's plot plan guide asks for the lot's dimensions with each property line labelled PL.
“Property dimensions (length and width) and property lines indicated. Label all property lines with “PL” notation”
The footprint of every structure, its use and the zoning district.
“Building footprint of all structures on property, proposed use and zoning district”
Every setback, measured from the property lines.
“All setback dimensions, front, rear, and sides measured from property lines, and any projections into required setbacks dimensioned”
A north arrow, with north at the top of the sheet.
“North arrow (use directions with north located at top of sheet, and using assumed north rather than true north)”
Easements.
“13. Easements”
A lot coverage calculation.
“22. Lot coverage calculation”
Arrows for the roof slope and the drainage flow.
“Indicate with arrows the slope of roof and the drainage flow directions.”
Who may draw the plan
The homeowner guide says plans for nonstructural work can be drawn by anyone.
“Plans for nonstructural alterations, such as door and window replacements, can be drawn by anyone.”
Plans and calculations for structural work must be stamped by a California-licensed architect or engineer.
“For projects involving structural modifications, plans and calculations are typically required and must be prepared, signed and stamped by an architect or engineer licensed in the state of California.”
For a new accessory structure, a two-story project needs a structural analysis by a licensed structural engineer.
“Structural analysis required by a licensed structural engineer for two-story projects.”
The plot plan guide, revised in 2001, lists a seal in the title block and names an architect, engineer or designer.
“Architect/engineer/designer’s seal”
Sheet size
The plot plan sheet is between 11 by 17 inches and 24 by 36 inches.
“Sheet size: Not larger than 24” by 36”, nor smaller than 11” by 17””
Where to file
A new accessory structure is applied for online through Electronic Plan Review.
“Electronic Plan Review online submittal”
Before you file
Lot lines are drawn from county GIS records. This is not a boundary survey. Some permit offices require a stamped plan or a survey. Check with yours first. The permit office is City of Santa Monica Building and Safety. Rules change: the quotes above are what the city's pages said on November 19, 2026.